Plate inspection & GD&T
Datums and datum systems
A datum is the reference a geometric tolerance borrows its direction and position from — not a line on the part, but an ideal reference established when the datum feature touches a precise substitute surface such as the plate, a mandrel or a V-block. Order matters: primary removes three degrees of freedom, secondary two, tertiary one.
On this page
Datum, datum feature, simulated datum feature
On the bench the datum is not imagined; it is physical contact. A part’s “datum A” is what the part’s face and the plate’s face make together.
The datum feature is what the drawing names: a real face, edge or hole on the part, boxed with a letter per GB/T 1182-2018 / ISO 1101:2017. The datum is the ideal reference derived from it, used to orient and locate the tolerance zone.
The simulated datum feature is the precise stand-in — the working face of a surface plate, the outside of a mandrel, the groove of a V-block — that touches the actual surface so the datum can be established at all (GB/T 17851-2022; ISO 5459:2024).
The three-plane datum system for a prismatic part and 3-2-1
A datum system works in the order the drawing lists it. The primary datum seats against the plate and takes three of the part’s six degrees of freedom (one translation, two rotations). The secondary datum, now seating against the already-seated part, takes two more; the tertiary takes the last one: 3 + 2 + 1 = 6, and the part cannot move.
| Datum | Degrees of freedom removed |
|---|---|
| Primary | 3 (1 translation, 2 rotations) |
| Secondary | 2 |
| Tertiary | 1 |
Swap the order and the seat changes: the same part, gauged A-B-C and B-A-C, rests differently and can read different form errors. The letter order on the drawing is part of the specification, not a label list.
Establishing datums on the plate
The bench recipe mirrors the theory. Datum face down on the plate: that contact is the primary datum. Slide the part against a square or rest it in a V-block until the secondary feature touches: that contact is the secondary datum. A stop or a third touch fixes the last direction. Only then mount the indicator and read.
The quality of every later number is capped by the quality of this seating — a wobbly datum face multiplies its own waviness into every “parallelism” read from it.
Why the datum comes before the reading
The direction-, position- and runout tolerances covered in this lesson measure against a datum: parallelism, perpendicularity, position, and runout all need one — the runout check is a worked case in measuring runout. A dial indicator waving in the air tells you the shape of nothing; once the part is seated on its datums, the same indicator reads a deviation that can be judged.
Shape tolerances are the exception and the contrast: flatness and straightness need no datum because their zones float free — see flatness and straightness. Reading the drawing therefore starts with asking “does this tolerance need a datum, and in which order?” (inspection characteristics).
Datum targets
When the feature is big, rough or warped, the drawing may pin the datum to a small region instead of the whole surface — a datum target, a point, line or area marked on the feature (GB/T 1182-2018). The rest of the surface then lives inside the tolerance, not in the datum.
In KELIBRON
The lab does not have plates, boxes or V-blocks yet. The current course materials describe the datum-before-runout rule, but the public lab does not yet perform that check. For now, the shaft-outside scene can be used only to practise stable seating and repeatable contact; its diameter result is not a datum-based geometric-tolerance result.
References
- GB/T 17851-2022《产品几何技术规范(GPS) 几何公差 基准和基准体系》 · 国家市场监督管理总局、国家标准化管理委员会
- ISO 5459:2024 — Geometrical product specifications (GPS) — Geometrical tolerancing — Datums and datum systems (3rd edition, 2024-10; replaces ISO 5459:2011) · ISO
- GB/T 1182-2018《产品几何技术规范(GPS) 几何公差 形状、方向、位置和跳动公差标注》 · 国家市场监督管理总局、国家标准化管理委员会
- ISO 1101:2017 — Geometrical product specifications (GPS) — Geometrical tolerancing — Tolerances of form, orientation, location and run-out (confirmed 2022) · ISO
- 金莹 主编,《公差配合与技术测量》,清华大学出版社,2014(2024 年第 4 次印刷),ISBN 978-7-302-37145-8 (cited by number; no public page) · 清华大学出版社
How the guides are checked against these sources: About KELIBRON.
Practise the shared basics on a caliper
Questions
What is the difference between a datum and a datum feature?
The datum feature is the real surface named on the drawing; the datum is the ideal reference built from it when that surface touches a precise substitute such as the plate. You measure against the datum, but you seat the datum feature.
Why does the order A-B-C matter?
Each datum removes degrees of freedom in sequence: 3, then 2, then 1. A different order seats the part differently, so the tolerance zone sits differently — the order is part of the specification.
Which tolerances need a datum?
Orientation, location and runout tolerances all need one or more datums. Form tolerances (flatness, straightness, roundness, cylindricity) do not — their zones are free-floating by definition.
Practise the basics first
Cleaning, zero checks, square positioning, light even force and reading to the scale interval are the same on every instrument; practise them in a caliper scene.
Related guides
Tolerances and decisionsTolerances and fits basicsA toleranced size gives a nominal size and two deviations.
Tolerances and decisionsLooking up IT grades and fundamental deviationsA tolerance class such as h6 is a letter for the fundamental deviation, which sets where the band sits, and a number for the standard tolerance grade, which sets how wide it is.
Tolerances and decisionsAcceptance limits and the safety margin AUnder GB/T 3177-2009 a plain size is accepted by acceptance limits.