Measuring methods
Gear span and chordal thickness
Span over teeth is the length between two parallel planes tangent to opposite flanks. For a zero profile-shift spur gear of module 2.5 mm, 24 teeth, 20° and a span of 3, the derived length is 19.291 mm.
On this page
What is a span measurement?
A disc micrometer, or a caliper used the same way, closes two parallel faces across several teeth. The length is the base tangent, not the tip diameter.
The public lab can already check a gear tip with a caliper in the gear-tip scene. That check does not say the tooth thickness is right.
How is 19.291 mm obtained?
For a zero profile-shift spur gear the derived span is W = m cos α [(k − 0.5)π + z inv α], with inv α = tan α − α and α in radians. It is a geometric derivation, not a value copied from a tolerance table.
With m = 2.5 mm, z = 24, α = 20° and k = 3: inv 20° = 0.014904, and W = 2.5 × cos 20° × [π × 2.5 + 24 × 0.014904] = 19.291 mm.
What do the numbers in this article mean?
This lesson rounds 19.291 mm to 19.29 mm and attaches a teaching band of −0.05/−0.12. That band is a teaching value used in this article. It is not an allowance copied from GB/T 10095.1-2022.
GB/T 10095.1-2022 is the current Chinese standard for flank-tolerance grades. GB/T 13924-2008 is the current inspection code. Their tables were not opened, so no grade number is given here.
How is chordal thickness different?
A gear tooth caliper reads chordal thickness and chordal addendum, not the span. GB/T 6316-2008 is the current standard for vernier, dial and digital gear tooth calipers. Its maximum permissible error was not opened, so none is stated.
On the same zero-shift gear, reference-circle chordal thickness is s = m z sin(π / (2z)) = 3.924 mm, and the chordal addendum is 2.564 mm. Those are derived checks of the arithmetic, not acceptance limits.
What is actually selectable?
The public lab does not have a disc micrometer for span measurement, and the span task cannot be selected. A missing instrument must not be reported as a pass.
In this article’s teaching examples, 19.21 mm lies inside the teaching band and off both limits; 19.29 mm is above the teaching upper limit of 19.24 mm. These figures are teaching values, not standard-table or certificate values.
References
- GB/T 10095.1-2022《圆柱齿轮 ISO齿面公差分级制 第1部分:齿面偏差的定义和允许值》 · 国家市场监督管理总局、国家标准化管理委员会
- GB/T 13924-2008《渐开线圆柱齿轮精度 检验细则》 · 国家质量监督检验检疫总局、中国国家标准化管理委员会
- GB/T 6316-2008《游标、带表和数显齿厚卡尺》 · 国家质量监督检验检疫总局、中国国家标准化管理委员会
How the guides are checked against these sources: About KELIBRON.
Practise the shared basics on a caliper
Questions
Is span measurement the same as tip diameter?
No. Span is the length across opposite flanks. Tip diameter is a separate caliper check.
Is 19.291 mm a standard tolerance?
No. It is this article’s calculation for a zero-shift spur gear. The −0.05/−0.12 band is a teaching value used in this lesson, not a GB/T 10095.1 table value.
Does a tooth caliper read the span?
No. It reads chordal tooth thickness and chordal addendum. GB/T 6316-2008 covers that caliper.
Practise the basics first
Cleaning, zero checks, square positioning, light even force and reading to the scale interval are the same on every instrument; practise them in a caliper scene.
Related guides
Measuring methodsFinding the inspection characteristics on a drawingAn inspection characteristic is a requirement on the drawing that the part must meet and that someone has to check: a size with its tolerance, a size that takes the general tolerance, a geometric tolerance, a surface texture requirement, or a note that sets a requirement, plus any requirement added by the purchase order.
Measuring methodsHow to measure a machined partBuild a measurement plan from the drawing: list each feature and its limits, choose an instrument with suitable capability and access, decide the contact and measuring positions, then record every result.
Measuring methodsMeasuring common partsMeasure every diameter at several places along the part and in two directions 90° apart; the spread reveals taper and out-of-round.