Plate inspection & GD&T
Flatness and straightness: form errors
For the plate-and-indicator flatness check, support the part, sample the specified face and find the spread of the readings. For the level method, record equal-span tilts and accumulate them with their signs. These are sampled approximations, not a replacement for the specified formal evaluation.
On this page
Flatness with a dial indicator
For this plate-and-indicator check, support the workpiece, fix the stand, zero the indicator and read the specified grid across the face. GB/T 11337-2004《平面度误差检测》covers flatness detection methods.
The spread of the readings is the flatness error as an approximation: flatness ≈ max − min. The worked example: five points read +12, +4, −6, −2, −9 µm against the zero, so flatness ≈ 12 − (−9) = 21 µm = 0.021 mm — inside a 0.03 mm tolerance with 0.009 mm to spare.
| Point | Reading (µm) |
|---|---|
| 1 | +12 |
| 2 | +4 |
| 3 | −6 |
| 4 | −2 |
| 5 | −9 |
| Flatness (max − min) | 21 µm |
For disputes the approximation yields to the minimum-zone method of GB/T 11337-2004 — the smallest pair of parallel planes containing the surface. The judgement rules of that method are not quoted here because the standard text has not been read; the spread method stays the daily habit.
Straightness with a level: the pitch method
For the pitch method, move a frame level or autocollimator along the bed or rail in equal spans and record each tilt. GB/T 11336-2004《直线度误差检测》covers straightness detection methods. The instrument reads section tilt; for a level this corresponds to the height difference across its span.
At the common graduation of 0.02 mm/m, a 250 mm span gives 0.02 × 0.25 = 0.005 mm per division.
Add the signed section readings to form the deviation polyline; its peak-to-valley is a straightness approximation. Reading errors are carried into that sum, so keep the spans equal, the bridge stable and the reading procedure consistent.
A knife-edge straightedge and a light gap provide a quick qualitative check, not a numerical straightness result.
The tolerance zones, and why no datum
Per GB/T 1182-2018 (in line with ISO 1101:2017), flatness bounds a surface between two parallel planes spaced t apart, and straightness bounds a line between two parallel lines (in a plane) or two parallel planes (in space) spaced t apart. The zone of a form tolerance floats: it orients and positions itself to hug the actual surface, so the drawing gives it no datum.
Form checks here do not establish orientation to another feature. Compare the datum-related orientation and runout checks in datums and the runout check.
Reading the habits across to the lab
The two habits that make these methods work are already trainable in the lab: fix the gauge to a rigid support before reading (the dial-compare scene), and zero on a trusted reference before trusting a difference (gauge-block-30-compare). The lab cannot yet practise the grid discipline or the accumulation arithmetic.
In KELIBRON
The lab has indicator stands, but no surface-plate or level-based form-checking task. See surface plate and height gauge for the setup, and datums for the distinction between form and datum-related checks.
References
- JCGM 100:2008 — Evaluation of measurement data — Guide to the expression of uncertainty in measurement (GUM) · JCGM / BIPM
- GB/T 1182-2018《产品几何技术规范(GPS) 几何公差 形状、方向、位置和跳动公差标注》 · 国家市场监督管理总局、国家标准化管理委员会
- ISO 1101:2017 — Geometrical product specifications (GPS) — Geometrical tolerancing — Tolerances of form, orientation, location and run-out (confirmed 2022) · ISO
- GB/T 11337-2004《平面度误差检测》 · 国家质量监督检验检疫总局、中国国家标准化管理委员会
- GB/T 11336-2004《直线度误差检测》 · 国家质量监督检验检疫总局、中国国家标准化管理委员会
- 金莹 主编,《公差配合与技术测量》,清华大学出版社,2014(2024 年第 4 次印刷),ISBN 978-7-302-37145-8 (cited by number; no public page) · 清华大学出版社
How the guides are checked against these sources: About KELIBRON.
Practise the shared basics on a caliper
Questions
Does flatness need a datum?
No. Flatness and straightness are form tolerances with free-fitting zones. The orientation and runout checks compared in this lesson use datums.
Is max − min really the flatness error?
It is a spread approximation for sampled points. Formal assessment goes to the minimum-zone method of GB/T 11337-2004; depending on sampling and evaluation, the approximation can overstate or understate the full-surface result.
Why does the level method accumulate error?
Each section reading carries an error into the cumulative polyline. Use equal spans, stable support and a consistent reading procedure; do not assume that choosing a shorter span alone guarantees a better result.