Reading instruments
How to read a vernier caliper
To read a vernier caliper, take the whole millimetres just left of the vernier zero, then add the aligned line’s number times the least count. Do not estimate between lines. Check zero before measuring; subtract any signed zero error from the reading.
On this page
Reading steps
Read the main scale first, then the aligned vernier line. Before measuring, close the clean jaws and check zero; keep your eye square to the scale when reading.
- Read the whole millimetres on the main scale just left of the vernier zero line.
- Find the single vernier line that lines up exactly with a main-scale line.
- Multiply its number by the least count and add.
- Write the result to the least count (0.02 mm → two decimals, even digit in the last place).
Worked examples
- 0.02 mm vernier: zero past 40, line 13 lines up → 40 + 13 × 0.02 = 40.26 mm.
- 0.05 mm vernier: zero past 12, line 7 lines up → 12 + 7 × 0.05 = 12.35 mm.
- 0.1 mm vernier: zero past 23, line 4 lines up → 23 + 4 × 0.1 = 23.4 mm.
With a 0.02 mm vernier the last digit is always even (x.x0, x.x2 … x.x8). The figures on its plate (0, 1 … 9, and 0 or 10 at the last line, depending on the maker) mark every fifth line, i.e. tenths of a millimetre.
Zero error: positive and negative
Close the jaws. If the vernier zero lies right of the main-scale zero the zero error is positive; left of it, negative. Correct every reading: true value = reading − zero error (with its sign). Example: zero error +0.06 mm, reading 25.08 mm → 25.02 mm.
A vernier caliper cannot be re-zeroed; a digital one can (ORIGIN), a dial one by turning the bezel.
Bores and depths
The outside jaws, the inside jaws and the depth rod all move with the slider, so bores and depths are read on the same scale in the same way. On a caliper with separate knife-edge inside jaws the scale gives the bore directly; on models that measure bores with the outer faces of the lower jaws, add the jaw width marked on them.
- Bore: put the inside jaws in the bore, open until both touch, rock across for the largest reading, then read.
- Depth: rest the end of the beam flat on the reference face, push the depth rod to the bottom, then read.
Inch vernier (1/128 in)
Many vernier calipers also carry an inch scale in 1/16 in with a vernier of 8 divisions reading 1/128 in. Read sixteenths on the beam plus the coinciding vernier line × 1/128 in. Some inch verniers are graduated in thousandths and read 0.001 in instead.
Avoiding parallax
Look square onto the scales; at an angle the lines seem shifted. Many vernier plates are bevelled so their lines sit almost level with the main scale, which reduces parallax. KELIBRON’s readout view turns the camera square to the plate.
Least count (resolution) of a vernier
The least count of a 50-division vernier is 0.02 mm, of a 20-division vernier 0.05 mm and of a 10-division vernier 0.1 mm. A vernier reading is not estimated between lines.
A vernier with n divisions spread over (n − 1) mm has divisions of (n − 1)/n mm, each 1/n mm shorter than a main-scale millimetre. That difference is the least count.
The longer 39 mm vernier spreads 20 divisions over 39 mm: each is 1.95 mm, 0.05 mm shorter than 2 mm, so the least count is still 0.05 mm; the lines are further apart and easier to read.
| Vernier | Spans | Least count |
|---|---|---|
| 10 divisions | 9 mm | 0.1 mm |
| 20 divisions | 19 mm (or 39 mm) | 0.05 mm |
| 50 divisions | 49 mm | 0.02 mm |
For N vernier divisions equal to M main-scale divisions and for counting a negative zero error back from the end of the vernier, see least count of a vernier caliper.
References
- ISO 13385-1:2019 — Geometrical product specifications (GPS) — Dimensional measuring equipment — Part 1: Design and metrological characteristics of callipers · ISO
- JJG 30-2012《通用卡尺》检定规程 (cited by number; no public page) · 国家质量监督检验检疫总局
- JCGM 200:2012 — International vocabulary of metrology — Basic and general concepts and associated terms (VIM, 3rd edition) · JCGM / BIPM
- GB/T 21389-2008《游标、带表和数显卡尺》 · 国家质量监督检验检疫总局、国家标准化管理委员会
How the guides are checked against these sources: About KELIBRON.
Watch it done
Played back in the lab from domain commands; the reading and any verdict come from the measurement model.
Practise in the lab
Vernier caliperRead a vernier caliper on a Ø25 shaft (readout view)Open in the lab →
Vernier caliperVernier caliper: bore of a blind partOpen in the lab →
Vernier caliperVernier caliper: depth of a blind boreOpen in the lab →
Vernier caliper · wrong useWrong use: vernier zero not checkedOpen in the lab →
Questions
What is the least count of a vernier caliper?
Usually 0.02 mm (50-division vernier); 0.05 mm (20 divisions) and 0.1 mm (10 divisions) are also made.
Do you estimate between lines on a vernier caliper?
No. A vernier caliper is read to its least count without estimation (in school physics a micrometer is read with one further estimated digit).
How do I correct a negative zero error?
Subtract the signed zero error: with −0.04 mm, a reading of 18.30 mm gives 18.30 − (−0.04) = 18.34 mm.
Try it yourself
Open the same setup in the 3D lab and take the reading yourself.
Related guides
Reading instrumentsHow to read and use a caliperCheck zero with the jaws closed, hold the part deep in the jaws and square to the beam, close with light, even force, then read: on a vernier, the main-scale millimetres plus the coinciding line × 0.02 mm; on a dial, millimetres plus the needle’s hundredths; on a digital caliper, the display.
Reading instrumentsPhysics practical: length measurementThe Class 11 vernier caliper experiment (NCERT Experiment 1) has three parts: the diameter of a sphere or cylinder, the sides of a block for its density, and a beaker’s internal diameter and depth for its volume.
Reading instrumentsLeast count of a vernier caliperLeast count (vernier constant) = 1 main scale division − 1 vernier scale division = 1 MSD ÷ n (n vernier divisions span n − 1 MSD): 1 mm ÷ 10 = 0.1 mm, ÷ 20 = 0.05 mm, ÷ 50 = 0.02 mm.